Notification of abnormal lab test results in an electronic medical record: do any safety concerns remain?

Background
Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions.

Methods
We studied 4 alerts: hemoglobin A1c ≥15%, positive hepatitis C antibody, prostate-specific antigen ≥15 ng/mL, and thyroid-stimulating hormone ≥15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up.

Results
Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84).

Conclusions
Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.

Abstract
Singh, Hardeep; Thomas, Eric J.; Sittig, Dean F.; Wilson, Lindsey; Espadas, Donna; Khan, Myrna M.; Petersen, Laura A., The American Journal of Medicine, 123(3), 238-244, DOI: 10.1016/j.amjmed.2009.07.027

More bibliographic information.

8 March 2010 | Categories: Science | Country: United States | EHR: EHR, EHR USA | Tag(s): Alert/Reminder, emr, Health Information Technology, lab results, Patient Safety
You can leave a response, or trackback from your own site.
If you appreciate our news pages, don't forget to subscribe or try the NEW ICMCC toolbar!

Leave a Reply

Back to News Page

subscribe

ICMCC is member of

IFMBE

WABT

© ICMCC 2004-2011

Log in